Home > Industrial Products > FP0R, Panasonic, Programmable Controllers
Skip to product information
1 of 5

FP0R, Panasonic, Programmable Controllers

FP0R, Panasonic, Programmable Controllers

SKU: PROGRAMMABLE-CONTROLLERS-FP0R

Regular price $94.00
Regular price Sale price $94.00
Sale Sold out
Type

RuffRuff App RuffRuff App by Tsun

Performance specifications (FP0R Control units)

Product type of FP0R control unit C10
(Relay output type only)
C14
(Relay output type only)
C16
(Transistor output type only)
Programming method / Control method Relay symbol / Cyclic operation
Number of
I/O points
No expansion
(Control unit only)
10 points
[Input: 6,
Relay output: 4]
14 points
[Input: 8,
Relay output: 6]
16 points
[Input: 8,
Transistor output: 8]
With expansion 1
Same type of control and expansion units (Note)
Max. 58 points Max. 62 points Max. 112 points
With expansion 2
Mix type of relay and transistor units (Note)
Max. 106 points Max. 110 points Max. 112 points
Program memory EEPROM (no backup battery required)
Program capacity 16 k steps
Number of
instructions
Basic 110 approx.
High-level 210 approx.
Operation speed Up to 3,000 steps Basic instructions: 0.08 μs min. Timer instructions: 2.2 μs min.
High-level instructions: 0.32 μs (MV instruction) Min.
3,001st and later steps Basic instructions: 0.58 μs min. Timer instructions: 3.66 μs min.
High-level instructions: 1.62 μs (MV instruction) Min.
Operation
memory
Relay Internal
relay (R)
4,096 points
Timer / Counter
(T / C)
1,024 points
Memory area Data register (DT) 12,315 words
Index register (IX, IY) 14 words (IO to ID)
Master control relay points (MCR) 256 words
Number of labels (JMP and LOOP) 256 labels
Differential points Equivalent to the program capacity
Number of step ladder 1,000 stages
Number of subroutines 500 subroutines
Special
functions
High speed counter (HSC) Single-phase 6 points (C10: Single-phase 4 points) (50 kHz max. each) or 2-phase 3 points (C10: 2-phase 2 points) (15 kHz max. each) (Note)
Pulse output Not available 4 points (50 kHz max. each) 2 channels can be controlled individually.(Note)
PWM output Not available 4 points (6 Hz to 4.8 kHz)
Pulse catch input
/ interrupt input
Total 8 points (with high speed counter)
Interrupt program Input: 8 programs (6 programs for C10 only) / Periodic: 1 program / High speed counter match, Pulse output match: 4 programs
Periodical interrupt In units of 0.5 ms: 0.5 ms to 1.5 sec. / In units of 10 ms: 10 ms to 30 sec.
Constant scan In units of 0.5 ms: 0.5 ms to 600 ms
RS-232C port One RS-232C port is mounted on each of C10CRS, C10CRM, C14CRS, C14CRM, C16CT, C16CP, C32CT, C32CP, T32CT, T32CP, F32CT and F32CP type
(3P terminal block) Transmission speed (Baud rate): 2,400 to 115,200 bits/sec, Transmission distance: 15 m 9.843 ft. Communication method: half duplex
RS-485 port One RS-485 port is mounted on each of C10MRS, C14MRS, C16MT, C16MP, C32MT, C32MP, T32MT, T32MP, F32MT and F32MP type(3P terminal block)
Transmission speed (Baud rate): 115.2 kbps (It is possible to change to 19.2 kbps by the setting.), Transmission distance: 1,200 m 3,937 ft, Communication method: half duplex
Maintenance Memory
backup
Program and
system register
Stored program and system register in EEPROM
Operation
memory
Stored fixed area in EEPROM
Counter: 16 points
Internal relay: 128 points
Data register: 315 words
Self-diagnostic
function
Watchdog timer (690 ms approx.), Program syntax check
Real-time clock
function
Not available
Other functions Rewriting in RUN mode (Simultaneous rewriting capacity: 512 steps), Download in RUN mode (All programs), Password function (4-digit, 8-digit), Read protection setting
Product type of FP0R control unit C32
(Transistor output type only)
T32
(Transistor output type only)
F32
(Transistor output type only)
Programming method / Control method Relay symbol / Cyclic operation
Number of
I/O points
No expansion
(Control unit only)
32 points
[Input: 16, Transistor output: 16]
32 points
[Input: 16, Transistor output: 16]
With expansion 1
Same type of control and expansion units (Note)
Max. 128 points Max. 128 points
With expansion 2
Mix type of relay and transistor units (Note)
Max. 128 points Max. 128 points
Program memory EEPROM (no backup battery required)
Program capacity 32 k steps
Number of
instructions
Basic 110 approx.
High-level 210 approx.
Operation speed Up to 3,000 steps Basic instructions: 0.08 μs Min. Timer instructions: 2.2 μs Min.
High-level instructions: 0.32 μs (MV instruction) Min.
3,001st and later steps Basic instructions: 0.58 μs Min. Timer instructions: 3.66 μs Min.
High-level instructions: 1.62 μs (MV instruction) Min.
Operation
memory
Relay Internal
relay (R)
4,096 points
Timer / Counter
(T / C)
1,024 points
Memory area Data register (DT) 32,765 words
Index register (IX, IY) 14 words (IO to ID)
Master control relay points (MCR) 256 words
Number of labels (JMP and LOOP) 256 labels
Differential points Equivalent to the program capacity
Number of step ladder 1,000 stages
Number of subroutines 500 subroutines
Special
functions
High speed counter (HSC) Single-phase 6 points (50 kHz max. each) or 2-phase 3 points (15 kHz max. each) (Note)
Pulse output 4 points (50 kHz max. each) 2 channels can be controlled individually.(Note)
PWM output 4 points (6 Hz to 4.8 kHz)
Pulse catch input
/ interrupt input
Total 8 points (with high speed counter)
Interrupt program Input: 8 programs (6 programs for C10 only) / Periodic: 1 program / High speed counter match, Pulse output match: 4 programs
Periodical interrupt In units of 0.5 ms: 0.5 ms to 1.5 sec. / In units of 10 ms: 10 ms to 30 sec.
Constant scan In units of 0.5 ms: 0.5 ms to 600 ms
RS-232C port One RS-232C port is mounted on each of C10CRS, C10CRM, C14CRS, C14CRM, C16CT, C16CP, C32CT, C32CP, T32CT, T32CP, F32CT and F32CP type
(3P terminal block) Transmission speed (Baud rate): 2,400 to 115,200 bits/sec, Transmission distance: 15 m 9.843 ft. Communication method: half duplex
RS-485 port One RS-485 port is mounted on each of C10MRS, C14MRS, C16MT, C16MP, C32MT, C32MP, T32MT, T32MP, F32MT and F32MP type(3P terminal block)
Transmission speed (Baud rate): 115.2 kbps (It is possible to change to 19.2 kbps by the setting.), Transmission distance: 1,200 m 3,937 ft, Communication method: half duplex
Maintenance Memory
backup
Program and
system register
Stored program and system register in EEPROM
Operation
memory
Stored fixed area in EEPROM
Counter: 16 points
Internal relay: 128 points
Data register: 315 words
Backup of the entire area by FeRAM
(without the need for a battery)
  Backup of the entire area by a built-in secondary battery  
Self-diagnostic
function
Watchdog timer (690 ms approx.), Program syntax check
Real-time clock
function
Not available Available Not available
Other functions Rewriting in RUN mode (Simultaneous rewriting capacity: 512 steps), Download in RUN mode (All programs), Password function (4-digit, 8-digit), Read protection setting

More Specifications

Weight: C10: 100g, C14: 105g, C16: 85g, C32: 115g, T32: 115g, F32: 120g 

If you have any questions--about product, cooperation or wholesales, please feel free to leave message below.

View full details

Message